352-(.7 &+521,21< 35$:(0 $87256.,0 867$:$ = /87(*2 '] 8 ... · p p 2 2 3-1-1-1-1 p k2/m13 pð p p p...

Post on 12-Aug-2020

0 views 0 download

Transcript of 352-(.7 &+521,21< 35$:(0 $87256.,0 867$:$ = /87(*2 '] 8 ... · p p 2 2 3-1-1-1-1 p k2/m13 pð p p p...

p

p

2

2

3

-1

-1

-1

-1

P

K2/M13

52,75m²

P

P

P

K3/M10

62,75m²

P

K2/M14

46,32m²

K2/M15

67,08m²

K2/M16

40,88m²

A

A

P

K3/M11

72,64 m²

P

K3/M12

59,86m²

P

K1/M10

62,87m²

P

K1/M11

72,64 m²

P

K1/M12

59,86m²

160x200

-1 -1

-1 -1

-1-1

-1-1

-1

-1

-1

-1

-1 -1

-1-1

-1

-1

-1

-1

-1

-1

-1 -1

-1 -1

-1 -1

Treść rys.:

Temat:

A.Wsół, J.Micór- Architekci sp.p. WROCŁAW, ul. PADEREWSKIEGO 23 tel/ fax (071) 3481516 / 3481718

Inwestor:

Nr rys.

Skala:

Data:

Stadium:

Podpis:

EMKA INWEST Sp. z o.o.

RZUT 3 PIĘTRA

Sprawdzający:

Architektura:

mgr inż. arch. Anna Wsół

mgr inż. arch. Joanna Micór

Współpraca: arch. Magdalena Kapa ,arch. Joanna Mazur,arch.Jarosław Jakiel

09

51-114 Wrocław, ul. Obornicka 113F/7.

B

B

9x1

6

30

S1

S2

p p

p p

p p

p

p

p

pp

p

p p

p

p p

p

p

p

p

p

p

p

p

p

p

p

p

p

pp

p

p

pp

p

p

p

pp

p

1

1

3

1 1

2 2

3 3

1 1 2 2

3 3

1

11

22

2

33

3

1

2

3

1

2

1

1 1

2 2

2

3

3

3

-1

-1-1

p

-1

p

1

2

31

2

3

1 1

2 2

33

1

1

2

2

3

3

3

3 1

12

2

3

3

1

1

2

2

1

12

3

3

1

1

2

2

2

3

3

1

1

1

1

2

2

2

2

3

3

3

3

1

2

3

11

1

2

2

2

3 3

3

22 11

33

1

1

2

2

3

3

1 1

2 2

3 3

2 2

1

1

33

9x1

6

30

9x1

6

30

9x1

6

30

S2

S3 S2

S1

3

9x1

6

30

9x1

6

30

K1 K2

K3

C

C

DD

fragment działki nr : 156/4, 156/15; AM-19; obręb: BRZEG DOLNY

PROJEKT CHRONIONY PRAWEM AUTORSKIM - USTAWA Z 4 LUTEGO 1994. (Dz. U z 2000r. Nr 80, poz. 904) ZWIELOKROTNIANIE EGZEMPLARZY, ODSPRZEDAŻ LUB INNE WPROWADZANIE DO OBROTU ORAZ OPRACOWANIA ZALEŻNE W POSTACI KONCEPCJI OSTATECZNEJ I PROJEKTU BUDOWLANEGO LUB WYKONAWCZEGO BEZ ZGODY AUTORÓW JEST ZABRONIONE.

3

3

3

UWAGI:

1. WYMIARY SPRAWDZIĆ NA BUDOWIE.

2. PODSTAWĄ REALIZACJI OBIEKTU JEST ZATWIERDZONY PROJEKT BUDOWLANY I ODPOWIEDNIE BRANŻOWE PROJEKTY WYKONAWCZE.

3. WSZYSTKIE PRACE MUSZĄ BYĆ WYKONYWANE ZGODNIE Z ZASADAMI SZTUKI BUDOWLANEJ Z ZACHOWANIEM SZCZEGÓLNEJ OSTROŻNOŚCI I POD STAŁYM NADZOREM OSÓB UPRAWNIONYCH.

4. WSZYSTKIE ROBOTY BUDOWLANO- MONTAŻOWE Z ZASTOSOWANIEM ROZWIĄZAŃ SYSTEMOWYCH POWINNY BYĆ WYKONYWANE WEDŁUG TECHNOLOGII OKREŚLONEJ PRZEZ PRODUCENTA.

5. OPISY TECHNICZNE, SPECYFIKACJE TECHNICZNE WYKONANIA I ODBIORU ROBÓT STANOWIĄ INTEGRALNĄ CZĘŚĆ OPRACOWANIA.

6. WĘGARKI OKIEN I DRZWI DOCIEPLIĆ MIN. 3 CM. STYROPIANU.

7. WYSOKOŚĆ PARAPETU W POKOJACH I KUCHNIACH MIESZKAŃ - 85 CM, NA KLATCE SCHODOWEJ - 85 cm

8. WSZYSTKIE ZASTOSOWANE MATERIAŁY, ROZWIĄZANIA TECHNICZNE MUSZĄ ODPOWIADAĆ NORMOM BEZPIECZEŃSTWA P. POŻ, BHP, POSIADAĆ ATESTY I APROBATY TECHNICZNE

9. ZASTOSOWAĆ KSZTAŁTKI WENTYLACYJNE O ODPORNOŚCI OGNIOWEJ EI 60.

10.W POKOJACH I SYPIALNIACH ZALECA SIĘ WYKONAĆ WYGŁUSZENIE SZACHTÓW W POSTACI ŚCIANY LEKKIEJ O KONSTR. ALUMINIOWEJ, ODDALONEJ OD ŚCIANY WŁAŚCIWEJ O 1CM, POMIĘDZY PROFILAMI PŁYTY Z WEŁNY MINERALNEJ, NP:ROCKTON OD WNĘTRZA POM. PODWÓJNA PŁYTA GK.

11. DOJŚCIE NA DACH DRABINĄ SZER. MIN. 50 CM (ODSTEPY MIĘDZY SZCZEBLAMI MAKS. 30 CM, ODL. OD ŚCIANY MIN. 15 CM). OBRĘCZ OCHRONNA O ROZSTAWIE MAKS. 80 CM, PRĘTY PIONOWE O ROZSTAWIE MAKS. 30 CM OD 3 M NAD POZIOMEM PODŁOGI.

12. NA WIERZCHU KOMINA UŁOŻYĆ IZOLACJĘ Z PAPY ASFALTOWEJ, A NASTĘPNIE WYKONAĆ CZAPĘ BETONOWĄ. Z KAŻDEJ STRONY WYKONAĆ KILKUCENTYMETROWE KAPINOSY. KANAŁY WENTYLACYJNE ZAKOŃCZYĆ WYLOTAMI BOCZNYMI.

13. DŁUGOŚĆ KOMINA OD KONDYGNACJI PIWNICY OK. 13,30m

14. WSZYSTKIE INSTALACJE PRZEBIEGAJĄCE NA ŚCIANACH MIĘDZYLOKALOWYCH NIE PROWADZIĆ W BRUZDACH LECZ NATYNKOWO ABY NIE POGORSZYĆ AKUSTYKI POMIĘDZY LOKALAMI MIESZKALNYMI .ZAKAZUJE SIĘ MONTAŻU BATERII PODTYNKOWYCH W ŚCIANACH MIEDZYLOKALOWYCH.

-1 -1

S7

S7a

S7a

S7a

S7a

S7a

S7a

S7a

S7a

S7a

S7a

S7

S7

S7a

S7a

S3

OKNO Z NAWIETRZAKIEM

GRZEJNIK PŁYTOWY

GRZEJNIK DRABINKOWY, ŁAZIENKOWY

LEGENDA:

KUCHENKA ELEKTRYCZNA

UWAGA!

przy nieogrzewanych klatkach schodowych :

Uc(max) ściany klatki schodowej 0,3

przy ogrzewanych klatkach schodowych :

Uc(max) ściany klatek schodowych 1,0

Na ostatniej kondygnacji należy zastosować

wentylację wspomaganą porzez wentylator

na kratce lub nasadę hybrydową na kominie

sposób wspomagania do decyzji inwestora.

PIEC GAZOWY DWUFUNKCYJNY

Z ZAMKNIĘTĄ KOMORĄ SPALANIA

SZAFKA ROZDZIELACZOWA C.O.